2.3 LOCATING AND MOUNTING THE UNIT
Choose an appropriate location for the unit:
Within an area of the house where the ambient temperature is kept between 10°C (50°F) and 40°C (104°F);
Away from living areas (dining room, living room, bedroom), if possible;
So as to provide easy access to the interior cabinet for maintenance, and to the control panel on the side of the unit;
Close to an exterior wall, so as to limit the length of the insulated exible ducts to and from the unit;
HRV units only: close to a drain. If no drain is close by, use a pail to collect run-off;
Away from hot chimneys, electrical panel and other re hazards;
Within 6 feet of a power source (standard outlet).
Inspect the inside of the unit for damage. Ensure that
blower assembly, heat or energy recovery core, core
lters, insulation, dampers, etc. are all intact, then
reinstall the door.
VD0525
2.2 INSTALLATION KITS, TOOLS AND MATERIAL
The installation kit needed to perform most installations is IKSV1000 for Venmar units. Following are the tools and
material needed:
• Measuring tape
Phillips no. 2 or Robertson no. 2 screwdriver
• Small at blade screwdriver (for wall control connection)
Wire stripper (for wall control connection)
• Hammer and at blade screwdriver (for plenum connection installation only, to make holes in existing metal duct)
Scissors or utility knife (to cut duct tape)
• Duct tape
Tin snips or metal shear (for plenum connection installation only, to cut ductwork)
Aluminum duct tape (for plenum connection installation only)
• Jig saw
Caulking gun and caulking