ONBOARD INSTALLATION INSTRUCTIONS - Page 5

For SL22900EL. Also, The document are for others Sirius models: SLTC 97 900, SL22 900, SL22 900B, SL7 1200, SL107 S900, SLTC 107 G900, SL107 S1200

Loading ...
Loading ...
Loading ...
5
Min. 600mm - Max. 700mm for electric cooktops.
Min. 650mm - Max. 750mm gas cooktops.
If the rangehood is positioned above the max height
recommended, warranty may be compromised
as performance of the rangehood will be affected.
Measurement is taken from the top of the trivets to
the underside of the hood. (Fig.1)
The air being drawn can’t be conveyed through
or into a duct used to let out fumes from
appliances fed by energy other than electric
power (eg. centralized heating, radiators, water
heaters, etc.).
Attention: remove any possible PVC film from the
stainless steel, including the filters.
To externally vent, please comply with the
pertaining rules given by competent authorities.
Provide the room with an adequate ventilation
when a rangehood and appliances fed by energy
other than electric power (gas, oil, or coal stoves,
etc.) are used simultaneously. The rangehood,
when evacuating the air, could generate a
negative pressure in the room which can’t exceed
the limit of 0.04 mbar, in order to avoid the
suck of exhausts deriving from the heat source.
Therefore the room should be provided with air
intakes to allow a constant flow of fresh air.
If the rating label in the rangehood shows the symbol
, the appliance is built in class II° and it does not
need any earth connection.
If the rating label in the rangehood does not show
the symbol , the appliance is built in class I° and it
needs the earth connection.
When performing the electrical connections on the
appliance, please make sure that the current-tap
is provided with earth connection and that voltage
values correspond to those indicated on the label
placed inside the appliance itself.
Before carrying out any cleaning or maintaining
operations, the appliance needs to be switched off.
If the appliance is not provided with a non-separable
When ducting rangehood, options are as follows:
Roof vent - EASYROOF 150T/M
EASYROOF 200T/M
*Kit includes roof flashing
Download installation guide
Eave vent - EASYEAVE 150/200
Download installation guide
Wall vent - EASYWALL 150/200
Download installation guide
flexible cable and plug, or with another device
ensuring omnipolar disconnections from the grid,
with an opening distance between the contacts of at
least 3mm, then such disconnecting devices must be
supplied within the fixed installation.
If the fixed appliance is endowed with a supply cord
and a plug, the appliance has to be put in a place
where the plug can be reached easily.
The use of materials which can burst into flames
should be avoided in close proximity of the appliance.
When frying, please pay particular attention to fire
risk due to oil grease. Being highly flammable, fried
oil is especially dangerous. Do not use uncovered
electric grills. In order to avoid possible fire risk, all
instructions for grease-filter cleaning and for removing
eventual grease deposits should be strictly followed.
WARNING
600 - 700mm (electric)
650 - 750mm (gas)
600 - 700mm (electric)
650 - 750mm (gas)
(Fig. 1)
(Fig. 2a)
(Fig. 2b)
(Fig. 2c)
Dome
featured on
200mm kit
only
SIDE VIEW FRONT VIEW
Loading ...
Loading ...
Loading ...