7 TROUBLESHOOTING
Before calling customer service, please check that the appliance is correctly connected.
Any of the following cases are not covered by the warranty:
Damage caused by improper use, storage or maintenance
Damage caused by unauthorised disassembly and repair
Damage caused by misuse
Using the rangehood for commercial purposes
7.1 IN CASE OF EMERGENCY
In the event of an emergency you should:
Switch off all rangehood controls.
Switch the rangehood off at the power outlet and immediately unplug.
Contact Customer Service.
Some minor faults can be fixed by referring to the instructions given in the table below.
FAULT
COMMON CAUSE
COMMON SOLUTIONS
The lights work,
however the motor
does not work
The motor is blocked or
jammed.
Switch of the unit, arrange repair
by a qualified technician
The capacitor is damaged.
Neither the lights nor
the motor works
Beside the above mentioned, check the following:
Light globes are damaged
or blown
Replace the light globe
The power cord is loose.
Ensure that the rangehood is
correctly plugged in and the
power outlet is switched on.
The rangehood is
vibrating
The rangehood
canopy is not fixed
correctly.
Ensure that the internal safety
screws have been used and
are tight.
The unit is not hung
properly on the
bracket.
Remove the unit and check
whether the bracket is in
proper location, replace
back ensuring it fully fits the
bracket
Insufficient suction
Too long distance between
the rangehood and the
cooktop
Re-adjust the installation position,
ensuring that the minimum
distances are observed as per the
building code and relevant
standards.