Loading ...
Loading ...
Loading ...
9
Pre-Installation (continued)
WINDOW OPENING MEASUREMENTS
These instructions are for a standard double-hung window. You will need to modify them for other types of windows.
The air conditioner can be installed without the side curtain panels if needed to t in a narrow window. See the window opening
dimensions.
All supporting parts must be secured to rm wood, masonry or metal.
The electrical outlet must be within reach of the power cord.
Follow the dimensions in the table and illustration for your model.
Models A B
8K BTU
10K BTU
13 3/5 inch (345 mm) min 24 1/2 inch (622 mm) - 39 inch (991 mm)
12K BTU
14K BTU
15 1/5 inch (386 mm) min 24 9/10 inch (632 mm) - 39 inch (991 mm)
A
B
IF AC IS BLOCKED BY STORM WINDOW
Add wood as shown, or remove storm window before air conditioner is installed.
If storm window frame must remain, be sure the drain holes or slots are not caulked or painted shut. Accumulated rain water or
condensation must be allowed to drain out.
Storm window
frame or other
obstruction.
Sash
1 - 1/2 in. min
(38 mm)
Board thickness as
required, for proper
pitch to rear, along
entire sill. Fasten
with nails or screws.
Loading ...
Loading ...
Loading ...