27
- All Other Markets:
(*) NOTE:
* - Measure burner operating pressure at gas control outlet test point with burner
operating at ‘High’ setting. Operating pressure is ex-factory set through appliance
regulator and is not to be adjusted, apart from when carrying out gas conversion, if
required. (Refer to ‘Gas Conversion’ section for details).
BP8080G / GE BP8120G / GE BP8080G / GE BP8120G / GE BP8080G / GE BP8120G / GE
Main Burner Ø 4.30mm Ø 5.20mm Ø 2.50mm Ø 2.80mm Ø 2.40mm Ø 2.60mm
Pilot Burner 0.35 0.20 0.20
Aeration Clearance 30mm 30mm 30mm
Supply Pressure 1.13 - 3.40 kPa 2.75 - 4.50 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*) 0.76 kPa 0.60 kPa 2.5kPa 2.4kPa 2.5kPa 2.4kPa
Gas Regulator Cap Screw