10
NOTE: It is most important that this appliance is installed correctly and that operation is
correct before use. Installation shall comply with local gas, electrical and health and
safety requirements.
Waldorf Bratt Pans are designed to provide years of satisfactory service, and correct installation is essential
to achieve the best performance, efficiency and trouble-free operation.
This appliance must be installed in accordance with National installation codes and in addition, in
accordance with relevant National / Local codes covering gas, electrical, fire and health and safety.
Australia / New Zealand: - AS/NZS 5601 - Gas Installations.
- AS / NZS 3000 - Wiring Rules.
- AS / NZS 3500 - Plumbing and Drainage.
United Kingdom: - Gas Safety (Installation & Use) Regulations 1998.
- BS 6173 - Installation of Catering Appliances.
- BS 5440 1 & 2 - Installation Flueing & Ventilation.
- BS 7671 - Requirements for Electrical Installations.
Ireland: - IS 820 - Non - Domestic Gas Installations.
Europe: - EN1717 - Protection of Water Installations.
Installations must be carried out by authorised persons only. Failure to install equipment to
relevant codes and manufacturers specifications shown in this section will void the warranty.
Components having adjustments protected (e.g. paint sealed) by the manufacturer are only
to be adjusted by an authorised service agent. They are not to be adjusted by the installation
person.
Remove all packaging.
Check equipment and parts for damage. Report any damage immediately to the carrier and
distributor.
Ensure the 4 adjustable feet are fitted with the protruding centre screw.
Remove protective plastic coating from side panels.
Report any deficiencies to distributor who supplied bratt pan.
Check available gas supply is correct to as shown on rating plate located on bottom corner of front
right hand panel.
1. Installation must allow for a sufficient flow of fresh air for combustion air supply.
Combustion Air Requirements
2. Any gas burning appliance requires adequate clearance and ventilation for optimum and trouble-free
operation.
3. Never directly connect a ventilation system to appliance flue outlet.
4. Installation must include adequate ventilation means, to prevent dangerous build up of combustion
products.
5. Position Bratt Pan in its approximate working position.
6. All air for burner combustion is supplied from beneath unit. Legs must always be fitted and no
obstructions placed beneath or around base of unit, as obstructions will cause incorrect operation
and / or failure of appliance.
NOTE: Do not obstruct or block appliances flue. Never directly connect a ventilation system
to appliance flue outlet.
Natural Gas 19m
3
/hr 24m
3
/hr
LPG / Propane 20m
3
/hr 24m
3
/hr