1. The gas service to the dryer must
conform with local codes and
ordinances and the latest edition of
the National Fuel Gas Code ANSI
Z223.1/
PREINSTALLATION REQUIREMENTS
3-wire power supply cord (not
supplied)
OUTLET RECEPTACLE - NEMA 14-30R
receptacle to be located so the power
supply cord is accessible when the dryer is
in the installed position.
GROUNDING CONNECTION - See
“Grounding requirements” in Electrical
Installation section.
The dryer MUST employ a 3-conductor
power supply cord NEMA 10-30 type SRDT
rated at 240 volt AC minimum,
30 amp, with 3 open end spade lug
connectors with upturned ends or closed
loop connectors and marked for use with
clothes dryers. For 3-wire cord connection
instructions see “Electrical connection
(non-Canada) - 3-wire cord” in Electrical
Installation section.
OUTLET RECEPTACLE - NEMA 10-30R
receptacle to be located so the power
supply cord is accessible when the dryer is
in the installed position.
GROUNDING CONNECTION - See
“Grounding requirements” in Electrical
Installation section.
4-wire power supply cord
(not supplied)
The dryer MUST employ a 4-conductor
power supply cord NEMA 14-30 type SRDT
or DRT (as required) rated at 240 volt AC
minimum, 30 amp, with 4 open end spade
lug connectors with upturned ends or closed
loop connectors and marked for use with
clothes dryers. For 4-wire cord connection
instructions see “Electrical connection
(non-Canada) - 4-wire cord” in Electrical
Installation section.
Electrical requirements for
gas dryer:
CIRCUIT - Individual, properly polarized and
grounded 15 amp. branch circuit fused with
15 amp. time delay fuse or circuit breaker.
POWER SUPPLY - 2-wire, with ground, 120
volt, single phase, 60 Hz, Alternating
Current.
POWER SUPPLY CORD - Dryer is equipped with
120 volt 3-wire power cord.
GROUNDING CONNECTION - See
“Grounding requirements” in Electrical
Installation section.
Grounding type wall receptacle
Power cord with
3-prong grounded plug
Do not, under
any circumstances,
cut, remove,
or bypass the
grounding prong.
3-wire receptacle
(NEMA type 10-30R)
4-wire receptacle
(NEMA type 14-30R)
Gas supply requirements
WARNING
Improper grounding of the dryer may
cause serious injury or death. Check with
a licensed electrician if you are in doubt
as to whether the appliance is properly
grounded.
WARNING
EXPLOSION HAZARD
Uncoated copper tubing will corrode when
subjected to natural gas, causing gas leaks.
Use ONLY black iron, stainless steel, or
plastic-coated brass piping for gas supply.
NOTE
Dryers manufactured for sale in Canada
have factory-installed, 4-wire power
supply cord (NEMA 14-30).