22
CLEANING YOUR ICE MACHINE
Need more cleaner? Call Marvel Customer
Service at 616.754.5601.
Use only SafeCLEAN Plus™ Cleaner. Use of any other
cleaner may damage the finish of the evaporator and will
void the warranty. Follow safety and handling instructions
printed on the SafeCLEAN Plus™ bottle.
1. Press and Hold for 10 seconds
a. will appear in the display
b. Remove access shield
c. Remove all ice in bin
d. Remove any ice protruding from the ice dispenser
tube.
2. Insert the end of the cleaning tube into the ice
3. Press and release
a. will appear in the display
b. Mix 4 ounces of SafeCLEAN Plus™ with 2 quarts of
potable water.
4. Wait until appears in the display
a. Using the funnel and cleaning tube, slowly pour
3⁄4 of the cleaning solution into the dispenser
tube. Air and some water will exit the vent tube.
Remove cleaning tube.
b. Press and release
5. will appear in the display
a. The machine will circulate the solution, cleaning and
sanitizing the internal components, for
approximately 20 minutes.
b. While the machine is circulating the cleaning
solution, use 1/2 of the remaining cleaning solution and
a sponge to wipe down the inside of the ice bin and
scoop. Rinse with clean potable water.
6. When appears in the display, 3 soft tones will
sound, indicating the cleaning phase is complete.
Using the hose and funnel, slowly pour 1.5 quarts
(48 oz.) of clean potable water into the ice dispenser
tube. Air and some water will exit the vent tube.
Cleaning Tube
and Funnel
Ice
Dispenser
Tube
dispenser; slowly pour in approximately 1 quart of hot
(min. 100º F) potable water. This will melt ice inside the
dispenser tube. It is normal for some water to flow from
the ice dispenser tube and exit from the vent tube while
pouring. Omit this step if no ice is in the ice dispenser
tube.
Vent Tube
Figure 47
Figure 48
Under normal conditions cleaning should be done when
the display shows . You may initiate a cleaning cycle at
any time by pressing and holding the clean button for 10
seconds. will appear in the display indicating the start of
the cleaning process.
Failure to clean may reduce the quality and quantity of ice
produced. Once the clean cycle begins, it can be canceled
by pressing three times. Press once more to start
making ice. The clean cycle will automatically cancel if user
fails to activate control at steps 2, 3b, and 5b within 2
hours.
Required for cleaning:
Clean potable water
Bucket and cleaning sponge
Internal water filter (if applicable) —
S41016405-ACCY
SafeCLEAN Plus™ Cleaner — S41015681
Hose (7⁄16” ID x 9⁄16” OD) and funnel
Register your product at
marvelrefrigeration.com and receive a free
cleaning kit - S41016346-ACCY (cleaner,
hose, & funnel)
** available for purchase at marvelrefrigeration.com or
your local dealer
Select models include a water filter. The filter must
remain in place when using and cleaning the machine.
The filter is designed to filter out scale, sediment,
particles and cloudiness as well as reduce chlorine and
other off tastes and odors. Marvel recommends replacing
the filter (Part No. S41016405-ACCY) when you clean
your machine. The filter is available at
marvelrefrigeration.com.
Loading ...