Errors – causes and corrective measures
Cause Corrective measure
Temperature warning (g) flashing, display shows "err",
measurement not possible, measuring tool switches off
automatically after five seconds
Measuring tool is outside of
the operating temperature
range of 14 °F … 104 °F
(– 10 °C ... +40 °C).
Wait until the measuring tool has
reached operating temperature.
Then switch the measuring tool
back on.
All symbols flash, measurement not possible
Measuring tool faulty
Check the batteries and replace
them if necessary.
Fitted adapter (e) flashes, display shows "err", measurement
not possible
Adapter error:
– Faulty adapter
Send the adapter to the
aftersales service.
– Adapter has no connection
to the measuring tool.
Clean the contacts. If the adapter
still cannot connect to the
measuring tool after you have
done this, send the adapter to
the after-sales service.
Display shows "----" or "----" together with area measurement
indicator (f), measurement not possible
Measuring range exceeded 65 ft
(20m) or was lower than 0.5 ft
(0.15 m) or poor measuring
conditions.
Keep the measuring range < 65 ft
(20 m) or > 0.5 ft (0.15 m) and
read the notes on the measuring
range.
Area measurement smaller than
0.11 ft
2
(0.01 m
2
). Measurement
too small to be displayed.
Keep the area calculation
≥ 0.11 ft
2
(0.01 m
2
)
2610067140 3Z Laser Measurer 02-21.qxp_Layout 1 2/24/21 8:01 AM Page 2