For ARG6PV456. Also, The document are for others Summit models: ARS1PV, ARS1PV456, ARS1ML, ARG1PV, ARG1PV456, ARG1ML, ARS3PV, ARS3PV456, ARS3ML, ARG3PV, ARG3PV456, ARG3ML, ARS6PV, ARS6PV456, ARS6ML, ARG6PV, ARG6ML, ARS8PV, ARS8PV456, ARS8ML, ARG8PV, ARG8PV456, ARG8ML, ARS12PV, ARS12PV456, ARS12ML, ARG12PV, ARG12PV456, ARG12ML, ARS15PV, ARS15PV456, ARS15ML, ARG15PV, ARG15PV456, ARG15ML, ARS18PV ARS18PV456 ARS18ML MLRS18MC ARS18MLMC R18AS HCRG19 ARG18PV ARG18PV456 ARG18ML MLRG18MC ARG18MLMC R18AG HCRG18 ARG31PVBIADA, ARG31PVBIADA456, ARG31MLBIADA, ARS32PVBIADA, ARS32PVBIADA456, ARS32MLBIADA, ARG61PVBIADA, ARG61PVBIADA456, ARG61MLBIADA, ARS62PVBIADA, ARS62PVBIADA456, ARS62MLBIADA

PDF File Manual, 44 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
10
DETAILED TEMPERATURE CONTOLLER
GUIDE
Front Panel Operation
Set temperature (compressor’s top temperature) adjustment:
1. Press the SET button, the set temperature is displayed, then press the UP or DOWN
arrow to store and memorize. Press the SET button to exit the adjustment status and
display the product temperature. If no more buttons are pressed within 6 seconds, the
refrigerator product temperature will be displayed.
2. (Set temperature adjustment range: Parameter E1E2)
Manually start/stop defrosting:
Press HI/LO button, then press SET button and hold for 6 seconds to enter defrost status or to stop
defrost.
Display the sensor temperature (C13):
Press the DOWN arrow, the product temperature (or cabinet temperature) will flash display. After 6
seconds, will resume normal display.
Refrigeration LED:
During refrigeration the cooling snowflake LED is on. When temperature is constant, the LED is off.
Defrost LED:
During defrosting (if activated), the defrost LED is on. During the delay after defrosting, the LED
flashes.
Parameter set-up and settings (for all settings other than temperature setpoint):
Press SET button and hold for 6 seconds to enter the parameter setting (flash and display PAS).
After entering the correct password (factory default is 15), press SET and the display will show E1,
E2, …~do3 PAS in sequence. Press the UP or DOWN arrow and the value of the parameter will be
displayed and can be modified and stored. If no other buttons are pressed within 6 seconds, it will
exit, and the new value will be stored. NOTE: Only when in the inner parameter menu (display PAS)
and the correct password is entered can the parameter value be adjusted. If the wrong password is
entered, the parameter modification will be exited, although the set temperature adjustment is still
active. If you forget the password, you will need to resume the factory default settings.