STEP 11
Venting
• Depending on exterior ventilation chosen (see page 10), either exit the ducting through the ceiling or wall.
• Alwaysuserigidtypemetal/aluminumducttube(followthebuildingcodesinyourarea)tomaximizeairow.Makesure
thatthebackdraftapscanopen,toallowmaximumairow.Connecttheducttubetothevent/damperandsecurely
seal with certied aluminum or foil tape so that it is air tight. Please check the building codes in your city to learn which
tape product is recommended.
• Connect ductwork to damper. Use Duct Tape to ensure joint is sealed and air tight.
IMPORTANT:
• Observeallgoverningcodesandordinances.
• It is the customer’s responsibility to contact a qualified electrical installer.
• Ifcodespermitandaseparategroundwireisused,itisrecommendedthata
qualified electrician determine that the ground path is adequate. A 120-Volt, 60
Hz,AC-only,fusedelectricalsupplyisrequiredonaseparate15-ampcircuit,
fused on both sides of the line.
• DONOTgroundtoagaspipe.
• Checkwithaqualifiedelectricianifyouarenotsurethattherangehoodisproperlygrounded.
• DONOThaveafuseintheneutralorgroundcircuit.
IMPORTANT: Save this Installation Guide for electrical inspector’s use.
• Therangehoodmustbeconnectedwithcopperwireonly.
• The range hood should be connected directly to the fused disconnect (or circuit breaker) box through flexible
armored or non-metallic sheathed copper cable. UL/CSA listed strain relief must be provided at each end of the
power supply cable.
Installation
Figure 24 Figure 25
Figure 26 Figure 27