SWIMMING POOL HEAT PUMP
Manual
9. Troubleshooting
The pool heater is not running
Heat pump control set to OFF Turn the heat pump on
Desired water temperature is reached
Unit will automatically restart when
the water temperature goes below
the set point
Main breaker is tripped
Reset main breaker and restart heat
pump
Filter is dirty, restricting the water
flow.
Backwash and clean filter
The fan is running, but the compressor is not
The heat pump is in protection mode
In this case, there may be a delay
before restarting.
The unit is on defrost cycle
The compressor will automatically
start again a few minutes until it
has stopped three times
continuously.
There is no display and the fan is not running but the compressor is
running
Ask your electrician to verify your heat pump's power supply by checking over
the L1/L2/L3 connections in the unit's service box