JVC GY-HC900STU 2/3" HD Connected Cam Studio Camcorder Body Only

User Manual - Page 94

For GY-HC900STU.

PDF File Manual, 236 pages, Read Online | Download pdf file

GY-HC900STU photo
Loading ...
Loading ...
Loading ...
3
Set the time interval to start recording in
[Interval Rec].
To configure the setting, go to [System] B
[Record Set] B [Rec Mode] B [Rec Interval].
(A P154 [ Rec Interval 1 ] )
4
Start recording.
0
Press the [REC] button to record only the
number of frames specified in [Rec Frames]
and pause.
0
After the specified time in [Rec Interval] has
passed,
recording starts again to record only
the number of frames specified in [Rec
Frames] and pause.
0
Interval Rec continues until the recording is
stopped.
The display changes (“STBYN B RRECN
B “STBYN” (red text) B RRECN B
“STBYN” (red text)).
0
The
card slot status indicator lights up in red.
5
Press the [REC] button.
0
The card slot status indicator lights up in
green.
0
The display becomes “STBYN”.
Caution :
0
Do not remove the SD card during recording
(RRECN, red text) or recording pause (STBYN,
yellow text).
0
To remove the SD card during Interval Rec,
press the [CANCEL/RESET] button, check that
“STBYN” (white text) is displayed and the card
slot status indicator lights up in green before you
remove the card.
0
When the [TC GEN] selection switch is set to “F-
RUN”, the time code will be recorded in “R-
RUN”.
0
Audio cannot be recorded. The audio level
meter is grayed out.
(A P162 [Audio Level Meter] )
Splitting the Clips Freely
(Clip Cutter Trig) 0
You can split the clips freely without having to stop
recording during shooting.
1
Assign the “Clip Cutter Trig” function to
any of the user buttons.
(A P
45 [Assignment of Functions to User
Buttons] )
2
Press the user button that is assigned with
“Clip Cutter Trig” during shooting.
A clip cut icon (Q) appears on the display
screen for 3 seconds, and the clip is split.
.
100min
50min
282min
1
/60
F2. 8
AE
±0
ND1
/64
12 :34 : 56
ISO
102400
00: 00:00.00
1080 /30p
SDI IN
ITU709
COMPRESS
5 . 6 f t
B 5600
K
Memo :
0
Clips cannot be split again for a few seconds
after the operation is performed.
0
This item cannot be used when [Slot Mode] is
set to “Backup”.
0
This item cannot be used when
[Rec Mode] is
set to a value other than “Normal” or “Pre Rec”.
(A P154
[ Rec Mode 0 1 ] )
0
The split clips are recorded seamlessly without
interruptions in the video.
0
When Exchange
(U model) or MP4 (E model) is
selected, the clip cutter function cannot be used.
94
Special Recording 0
Shooting
Loading ...
Loading ...
Loading ...