Installation
Page 9
Drain Water Connection
Following connections are possible:
Drain hose to sink
Drain hose to waste water connection
Drain hose to sink connection
Fix the water drain hose properly to the piping.The hose has to reach at
one point a height between 400 and 850 mm above the appliance
bottom line.An extension hose for the water drain hose must not exceed
a total length of 4m and must have the same diameter as the water drain
hose.
Hang the drain hose with the U-support over the edge of a sink with
adequate size.
Protect the U-support sufficiently against slipping.
The internal diameter of the stand pipe with vent-hole must be minimum
40 mm.
Put the drain hose for approx.80 mm in the wastewater pipe.
Attach the U-support and secure it sufficiently.
When connecting the drain hose to a sink trap with a drain hose spigot,
make sure that the drain hose is supported to the height of the bench.
Ensure the drain spigot has a minimum hole diameter of 15 mm and it
has been drilled out.
The incoming water temperature should not exceed 60°C.
2.Take note of the permitted water pressure extremes.
3.Connect the water inlet hose to an accessible water tap with a 3/4” BSP connector (see fig.A). Ensure that there is no kink
in the inlet hose that could restrict the flow of water. A 90° bend requires a minimum height of 200 mm for a kink-free curve.
Ensure incoming water is clear. If the water pipes have not been used for a long period of time, let the water run to
make sure it is clear with no impurities. Not doing so may result in the water inlet hose getting blocked and
damaging the appliance.
If required, use a filter insert to filter out deposits from the piping. The filter insert is available from your Authorised
Service Centre or Customer Care.
4.Tighten the hose coupling a further half turn after seal contact.
5.Check that the connection does not leak.
Lowest: 0.3 bar = 3 N/cm
2
= 30kPa
Where pressure is below 1 bar, contact a qualified plumber.
Highest: 10 bar = 100 N/cm
2
= 1MPa
Where pressure is above 10 bar, a pressure reduction valve must be installed. Contact a qualified plumber.