7. When measurement is completed, disconnect the
test leads from the object of measurement.
NOTE
If the value of voltage is unknown, use the maximum
measurement position (10A) and reduce the range until
proper readings are obtained.
Figure 4
Resistance Measurement
Resistance Ranges: 200Ω, 2000Ω, 20kΩ, 200kΩ, 20MΩ,
200MΩ
1. Plug the red test lead into the VΩmA terminal, then
plug the black test lead into the COM terminal.
2. Set the rotary switch to the appropriate
measurement in Ω range.
3. Connect the test leads to the object of measurement,
the measured value will appear on the display.
4. When measurement is completed, disconnect the test
leads from the object of measurement.
NOTE
The test leads can add 0.1Ω to 0.3Ω of error to the
resistance measurement. To obtain precise readings
in lowresistance measurement (200Ω), short-circuit