Loading ...
Loading ...
Loading ...
Installation
44
The appliance can work in the following
modes:
220-240 V 2~
3 x 2.5 mm² three-pole cable.
220-240 V 3~
4 x 2.5 mm² four-pole cable.
220-240 V 1N~
3 x 2.5 mm² three-pole cable.
380-415 V 2N~
4 x 2.5 mm² four-pole cable.
380-415 V 3N~
5 x 1.5 mm² five-pole cable.
Fixed connection
Fit the power line with an omnipolar circuit
breaker in compliance with installation
regulations. The circuit breaker should be
located near the appliance and in an easily
reachable position.
Connection with plug and socket
Make sure that the plug and socket are of
the same type.
Avoid use of adapters and shunts as these
could cause overheating and a risk of
burns.
The values indicated above refer
to the cross-section of the internal
conductor.
The aforementioned power cables
are sized taking into account the
coincidence factor (in compliance
with standard EN 60335-2-6).
Loading ...
Loading ...
Loading ...