Installation
43
EN
5. Drill the hole and insert a wall plug.
6. Attach the chain and push the appliance
to the wall.
5.5 Electrical connection
General information
Check the grid characteristics against the
data indicated on the plate.
The identification plate bearing the
technical data, serial number and brand
name is visibly positioned on the appliance.
Do not remove this plate for any reason.
Perform the ground connection using a wire
that is 20 mm longer than the other wires.
The chain length must be as short
as practicable to avoid appliance
tilting forward and also diagonal
to avoid appliance moving
sideways.
Power voltage
Danger of electrocution
• Have the electrical connection
performed by authorised technical
personnel.
• Use personal protective equipment.
• The appliance must be connected to
earth in compliance with electrical
system safety standards.
• Disconnect the mains supply.
• Do not pull the cable to remove the
plug.
• Use cables withstanding a temperature
of at least 90°C.
• The tightening torque of the screws of
the terminal board conductors must be
1.5 - 2 Nm.