Gas Approval
37
EN
A test point (for checking the gas pressure)
is supplied either with the regulator or as a
separate fitting in the case of ULPG
(propane) appliances.
Connection of the appliance to the gas
supply must be in accordance with the
requirements of AS5601. A ½” BSP
connector at the inlet is recommended and
the gas supply line to the appliance must be
of adequate length to allow sufficient
withdrawal of appliance for service or
disconnection and be:
1. annealed copper pipe or;
2. flexible hose according to AS/NZ1869
& be at least Class “B”, 10 mm diameter.
The appliance must be installed with
provision to allow the gas to be turned off
and disconnected for servicing and removal
of the appliance as required from the gas
supply. Before the appliance is operated
make certain all relevant parts are placed in
the correct position.
On completion of the installation, the
installer MUST check for gas leaks and test
each burner individually for the correct
flame. Once all burners have been tested
individually, turn all burners on together.
Warranty service calls do not cover these
adjustments! To check the operating
pressure of the appliance it is
recommended at least 2 large size burners
are used. Ensure appliance is secured to
wall when installation is completed.
N.G. The regulator supplied must be fitted
to the ½ BSP thread at the rear of the
appliance. An approved manual shut-off
valve must be installed. The N.G. regulator
must be checked and adjusted to 1.0kPa
after installation.
U.L.P.G. Can be connected to the inlet
fitting directly. Gas pressure must be
checked to confirm the appliance operating
pressure is 2.75kPA, the appliance test
point is the Rapid burner injector as shown
below.
1. Disconnect power.
2. Light the auxiliary burner and set to high
flame. Ensure all other burners are off.
3. Zero manometer, then apply 6 mm
flexible tubing (A) to seal over the Rapid
burner injector (B) and check the gas
pressure by pressing in the
corresponding burner control knob in,
then turning to high flame position.
Patent 2015101170. For enquires contact
Gas Approval onsulting Pty Ltd. Smeg license
037 for GSCS20265