Loading ...
Loading ...
Loading ...
19
EN
18
Frothing milk
We recommend that you use pasteurised or UHT milk that has been recently opened. Untreated milk does not give
the best results.
Pour the milk into your milk jug. Immerse the nozzle in the milk - Fig. 12.
Initiate the steam function as explained in the paragraph above.
Once your milk is frothy enough - Fig. 13 - again press the button to stop the cycle.
To remove any milk traces from the steam nozzle, place a container under the nozzle and restart a preparation with
steam (around 10 seconds).
The steam nozzle can be removed for more intense cleaning. Wash it out with water and a little washing up liquid and
a small non-abrasive brush. Rinse and dry it - Fig. 14. Before putting it back, ensure that the air inlet holes are not
blocked by any milk residues. If necessary, unblock them using the needle supplied - Fig. 15.
Do not wash the steam nozzle in a dishwasher.
To interrupt the steam function, simply press any button.
If the nozzle is obstructed, unblock it with the needle provided.
Steam can be produced for a maximum of 2 minutes per cycle.
After the steam function has been used, the nozzle can be hot, and we recommend that you wait for a few
moments before handling it.
Auto-cappuccino XS 6000 Set (sold separately)
This auto-cappuccino accessory enables you to make cappuccinos or lattes - Fig. 16. Connect the different parts to
each other. Ensure that you do not pierce the pipe by keeping the button in the correct place.
After removing the lid, fill the jug with milk - Fig. 17 and place a cup or glass under the auto-cappuccino nozzle - Fig.
18. Select the cappuccino or latte position on the special nozzle - Fig. 19.
Start the steam, as indicated in the chapter ‘Making drinks with steam’.
Once you have made the milk froth, place your cup under the coffee outlets and start a coffee cycle - Fig. 20.
To prevent the milk from drying on the auto-cappuccino accessory, ensure that you clean it thoroughly. You are advised
to wash it immediately by running a steam cycle with the accessory jug filled with water in order to clean the inside of
the nozzle. You can use the KRUPS liquid cleaner for this, available separately.
MAINTAINING YOUR APPLIANCE
Emptying the coffee grounds collector and the drip tray.
If the light flashes,
Remove, empty and clean the coffee ground collector - Fig. 21.
Replace the coffee grounds collector – Fig. 22
Remove, empty and clean the drip tray - Fig. 23.
The drip tray is equipped with floats to indicate when it needs to be emptied.
Put all parts back in place.
As soon as you remove the coffee grounds collector, you will have to empty it completely to avoid any overflow.
The light will remain on if the coffee drawer
(1)
area is not cleaned thoroughly and if the used grounds col-
lector is not pushed firmly into place or is incorrectly installed.
You cannot make espresso or coffee while the light is on or is flashing. The coffee grounds collector has a ca-
pacity of 9 coffees.
Rinsing of circuits
These 2 functions are available anytime, except if the appliance requests a ‘CLEAN’ and/or ‘CALC’ cycle.
Rinsing out the coffee circuit:
Place a container under the coffee nozzles. Press the button - Fig. 6 quickly to start a coffee circuit rinsing cycle,
which will automatically stop after around 40 ml.
Rinsing out the steam circuit:
Place a container under the steam nozzle and press the button for 3 seconds to start a steam circuit rinsing cycle,
which will automatically stop after around 300 ml.
Appliance cleaning program, 3 times a year (total duration: about 13 minutes)
For hygienic reasons and to preserve all best coffee avor we recommend you to clean the coffee system when the
machine asks you to, about 3 times a year.
To perform this cleaning you will need:
- 1 KRUPS cleaning tablet
- 1 container of minimum 600ml
several ows will follow one another
When to carry out this program?
When it is necessary to run a cleaning program, the appliance alerts you by ashing the CLEAN indicator light. This
program can only be accessed when the appliance requests it (approximately every 300 brews of coffee or espresso).
To comply with the warranty conditions, it is essential to perform the cleaning cycle when the appliance alerts you.
Follow the order of operations carefully
Use only KRUPS cleaning tablets (available on our KRUPS.com store)
How to start the automatic cleaning program?
1. Start the cleaning program by pressing the button . The CLEAN indicator becomes solid and the and
indicators ash.
2. Remove, empty, clean and replace the coffee grounds collector Fig 21-22 The indicator light go off.
3. Remove, empty, clean and replace the drip tray Fig 23.
4. Fill and replace the water tank.
5. Place the 600 ml container under the coffee nozzles Fig 24.
6. Open the maintenance hatch Fig 25.
7. Insert the KRUPS XS3000 cleaning tablet into the cleaning chute Fig 26.
8. Press the button to start the cleaning cycle
9. The cleaning phase (about 13 min) starts. Several water ows follow one another in several phases without any
necessary intervention. They allow the device to be rinsed and the cleaning residue to be removed.
10. The cleaning cycle is nished when the light stays on and the CLEAN light goes out, empty the drip tray.
Your device is ready to be used.
Important :
You do not have to run the cleaning program as soon as the appliance requests it, but you must do it reasonably
soon after. If cleaning is postponed, the alert message will remain displayed as long as the operation has not been
performed.
if you unplug your machine or if you turn it off during cleaning or in the event of electrical failure, the cleaning program
will resume the current step at the time of the incident.
It will not be possible to postpone this operation: rinsing the water circuit is mandatory.
If there is not enough water in the water tank when you start the program, the light will come on to warn you. Add
the appropriate amount of water to the container and cleaning will continue automatically.
If you unplug the appliance during cleaning, press the button, or there is an electrical power cut, the
cleaning program will start again from the beginning. In this case, another cleaning tablet may be neces-
sary. Make sure to carry out the full cleaning cycle to ensure good maintenance of your appliance.
The cleaning cycle is intermittent: do not put your hands under the water outlets E and W while the cycle
is in progress.
Only use KRUPS (XS3000) cleaning tablets. We cannot be held responsible for any damage that may result from the
use of tablets from other brands.
You can obtain cleaning tablets from KRUPS Service Centres.
Scale removal program - total duration: about 20 minutes
The quantity of scale deposited depends on the hardness of the water used. The appliance will automatically warn you
by the CALC light coming on when you need to proceed with scale removal.
This program is only accessible when the appliance requests it.
To benet from the guarantee conditions, it is essential to perform the appliances scale removal cycle
when informed to do so. Be sure to follow the procedure closely step by step. You can continue to use the appli-
ance when the light is on, but you are advised to perform the program as soon as possible.