Page 4
C
L
1. GROUNDING INSTRUCTIONS
This appliance must be grounded. In the event of an electri-
cal short circuit, grounding reduces the risk of electric shock
by providing an escape wire for the electric current. This
appliance is equipped with a cord having a grounding wire
with a grounding plug. The plug must be plugged into an
outlet that is properly installed and grounded.
NOTE:
A recessed “clock” outlet is recommended.
2. Position the electrical outlet within the space covered by the
decorative flue and where it will not interfere with the round
duct. Make sure the outlet is no further than 14” from where
the cord exits from the hood and that the outlet does not
interfere with a mounting bracket fastening area or where the
decorative flue touches the wall.
INSTALL THE WIRING
CENTER
LINE
5¼”
16
22
LOCATE
ELECTRICAL
OUTLET
WITHIN THESE
AREAS.
(Verify location
will not interfere
with duct,
mounting
brackets
and flue.)
INSTALL THE HOOD MOUNTING
BRACKET
1. Construct wood wall framing that is flush with interior surface
of wall studs.
Make sure:
a) the framing is centered over installation location.
b) the height of the framing will allow the mounting bracket
to be secured to the framing within the dimensions
shown.
2. After wall surface is finished, carefully center and level the
hood mounting bracket and secure it to wall framing with (3)
#8 x 1-1/2” mounting screws. Tighten the screws completely.
9
43-9⁄16” = bottom of hood 30” above cooktop
49-9⁄16” = bottom of hood 36” above cooktop
FRAMING BEHIND
DRYWALL
1
9
16
WALL STUDS
30" 31" 32" 33" 34" 35" 36"
8 Feet
43-9/16" 44-9/16" 45-9/16" 46-9/16" 47-9/16" 48-9/16" 49-9/16"
Desired Hood Distance Above 36" High Cooktop (see note 1)
Mounting Bracket Mounting Holes Location Above 36" High Cooktop
10 Feet
(see note 2)
Duct
Method
Ducted
Non-Ducted
Ducted
Non-Ducted
9 Feet
Ducted
Non-Ducted
43-9/16" 44-9/16" 45-9/16"
43-9/16" 44-9/16" 45-9/16" 46-9/16" 47-9/16" 48-9/16" 49-9/16"
43-9/16" 44-9/16" 45-9/16" 46-9/16" 47-9/16" 48-9/16" 49-9/16"
43-9/16" 44-9/16" 45-9/16" 46-9/16" 47-9/16" 48-9/16" 49-9/16"
43-9/16" 44-9/16" 45-9/16" 46-9/16" 47-9/16" 48-9/16" 49-9/16"
Notes:
1
A maximum height of 36” above the cooktop is recommended for best capture of cooking impurities. The
bottom of the hood MUST NOT BE LESS than 30” above the cooktop. Distances over 36” above the cooktop
are at the installer’s and user’s discretion - providing that the ceiling height and flue length permit.
2
Requires 10-ft. flue extension accessory - Model Number FXN53SS.
Ceiling
Height