Thermal & Optical Bi-spectrum Network Camera User Manual
10
Note
The settings vary according to different camera models.
Reflect Light Filter & Forklift Filter are mutually exclusive with VCA functions.
The filtering status will be displayed on the lower right of the interface.
4. Click Save.
3.3.2 Set Normal Mode
This function is used to measure the temperature of the whole scene and alarm.
Steps
1. Go to Configuration Temperature Measurement Basic Settings, and check Enable
Temperature Measurement.
2. Refer to Set Thermography Parameters to set the parameters.
3. Go to Configuration Temperature Measurement Advanced Settings, and select Normal.
4. Configure the parameters of normal mode.
Emissivity
Set the emissivity of your target. The emissivity of each object is different.
Distance
The distance between the target and the device.
Pre-Alarm Threshold
When the temperature of target exceeds the pre-alarm threshold, and this status keeps more
than Filtering Time, it triggers pre-alarm.
Alarm Threshold
When the temperature of target exceeds the alarm threshold, and this status keeps more
than Filtering Time, it triggers alarm.
Pre-Alarm Output and Alarm Output
Check Pre-Alarm Output and Alarm Output to link the pre-alarm or alarm with the connected
alarm device.
Temperature Sudden Change Alarm
When the temperature change exceeds the set sudden change alarm value within the set
cycle, the camera triggers an alarm.
Note
Temperature sudden change alarm is only supported by certain device models.