Haier AW12EH2VHD Arctic Series 208-230V 12,000 BTU Single-Zone Ductless Highwall Indoor Unit

User Manual - Page 87

For AW12EH2VHD.

PDF File Manual, 117 pages, Read Online | Download pdf file

AW12EH2VHD photo
Loading ...
Loading ...
Loading ...
Troubleshooting
See reverse side for
wiring diagram, relevant
color-coded test
positions, and sensor
resistance values.
Error Codes (Indoor/Outdoor)
F6/LED1: 12 Flash
F7/LED1: 11 Flash
F21/LED1: 10 Flash
F25/LED1: 13 Flash
E1/LED1: No Flash
E2/LED1: No Flash
Complete the “Check This First” Flow
Chart before continuing.
Models:
AW09EH2VHD/ASYW09URDWD
AW12EH2VHD/ASYW12URDWD
AW18EH2VHD/ASYW18URDWD
1U09EH2VHE/ASH109URDSE
1U12EH2VHE/ASH112URDSE
1U18EH2VHE/ASH118URDSE
Yes
Yes
Yes
Yes
No
No
No
No
Re-seat connector
Replace sensor.
Go to next step
to test the board
as well before
replacing sensor.
Replace main
board. Replace
sensor as well if
resistance was
incorrect in the
previous step.
Re-seat and
re-check sensor
resistance with a
Replace sensor
Start
Is connector plugged in and
seated securely?
Disconnect power and un-plug senor
connector from the board.
Check resistance across the set of
wires for the faulting sensor. Does
the resistance correspond to the
temperature located in the respective
chart ? (See Reverse side.)
Reconnect sensor to the board and re-apply power.
Check voltage between the two corresponding
solder joints or through the top of the Molex
Is the voltage ~5VDC?
Is the temperature at the
sensor out of operating
range (+/- 3%)?
ERROR CODES and Troubleshooting
PAGE 87
Loading ...
Loading ...