Haier AW12EH2VHD Arctic Series 208-230V 12,000 BTU Single-Zone Ductless Highwall Indoor Unit

User Manual - Page 56

For AW12EH2VHD.

PDF File Manual, 117 pages, Read Online | Download pdf file

AW12EH2VHD photo
Loading ...
Loading ...
Loading ...
Testing
3. Take note of connection location and carefully remove
each connector.
4. Remove the 2 screws mounting the boar
d in the box. They
in diagonal corners from each other.
Upper Louver Removal
1.
2. Locate and remove the two scr
ews mounting the upper
louver assembly to the case. They are on either end of the
assembly.
Lower Damper Assembly Removal
1.
2. Disconnect the condensate drain.
3. Locate and remove the two screws mounting the damper
assembly to the case.
4. Pull on the right end of the assembly and rotate the
bottom of the assembly outward.
front edge of the condensate drain pan into place then rotate
the bottom of the assembly into position.
Replace Fan Motor
1.
and bottom damper.
2. Remove the white plastic strap that hold the line set in
place on the right side of the unit.
3. Locate the locking tabs on the left side of the evaporator
and press them inward and pull the coil forward to remove.
IMPORTANT: Great care should be taken to when performing
this step. Excessively moving the lineset that connects to the
4. Slide the coil to the right to. The coil can now be gently
pulled away from the case. Only move the coil far enough
to access the four screws holding on the fan inlet faring.