Gas Conversion and Specifications
31
- Australia Only:
- New Zealand Only:
- UK Only:
- Export:
Main Burner Injectors 2.80mm. 1.70mm.
Regulator Spring (Colour) Green Spring Blue Spring
Supply Pressure 1.13 - 3.4 kPa. 2.75 - 5.0 kPa.
Operating Pressure 0.75 kPa 2.35 kPa
Main Burner Injectors 2.70mm. 1.70mm. 1.70mm.
Regulator Spring (Colour) Green Spring Blue Spring Blue Spring
Supply Pressure 20 mbar 30 - 37 mbar 28 - 30 mbar
Operating Pressure 10 mbar 25 mbar 24.2 mbar
Main Burner Injectors 2.80mm. 1.70mm.
Regulator Spring (Colour) Green Spring Blue Spring
Supply Pressure 1.13 - 3.4 kPa. 2.75 - 5.0 kPa.
Operating Pressure 0.75 kPa 2.42 kPa
Main Burner Injectors 2.80mm. 1.70mm. 1.70mm.
Regulator Spring (Colour) Green Spring Blue Spring Blue Spring
Supply Pressure 1.13 - 3.4 kPa. 2.75 - 5.0 kPa. 2.755.0 kPa.
Operating Pressure 0.75 kPa 2.35 kPa 2.35 kPa