9. Specifications
Model CS16USBWHG
Dimensions (H x W x D) 24.3 x 34.8 x 20.2 in. / 617 x 884 x 513 mm
Unit Weight 130.7 lb. / 59 kg
Load Capacity* 200 lb. / 90 kg
Charger/Hub Ports 16 x USB 2.0 A (Female); 1 x USB 2.0 B (Female); 1 x USB 2.0 Mini (Female)
Transmission Speed Up to 480 Mbps
Power Requirement Input: 100-240V, 2.5A, 50/60 Hz; Output: 5.0V, 2.4A Max (per USB port)
Operating Temperature 32° to 104° F / 0° to 40° C
Operating Humidity 5 to 95% RH, Non-Condensing
Enclosure Material Metal
*Full wall-mount load capacity requires a mounting surface capable of bearing the full load of the charging station and all connected components. Specifications may be subject to
change without further notice.
8. Ultraviolet Light Operation
Product A (max.) B (max.) B (min.) C (max.) D (max.)
TUV 8W
FAM/10X25BOX
288.3 mm 295.4 mm 293 mm 302.5 mm 16 mm
Usage
Once the user opens and closes the doors on the unit, the internal timer resets.
The timer cycles for 10 minutes when the “START” button is pressed.
1. Open the door of the CS16USBWHG Charging Station.
2. Insert devices and ensure the unit is plugged in.
3. Close the door. The “DOOR CLOSED / READY” LED will illuminate. Press the
“START” button and the UV lights will turn on automatically.
4. If the door is opened before the timer finishes its 10-minute cycle, the lights will
turn off and the timer will be reset for the next sanitizing cycle.
Note: Both charging station doors must be closed before the start button is pressed. The UV
lights will not turn on if either door is open. This helps ensure non-protected eyes or skin are
never exposed directly to UV light.
DOOR CLOSEDDOOR CLOSED
/ "READY" /
"
R
EAD
Y"
START BUTTON
UV LIGHT
CYCLE “ON
(10 min)
Maintenance and Troubleshooting
• Check that the lamp connector is securely attached to lamp.
• Check that the fuse is in good working order. Replace if necessary.
• Check that proper power is being supplied to the device and that the switch lights when turned on.
• Lamps should be cleaned every six months to remove any dust accumulation on the bulbs that might reduce the effectiveness of the UVC light.
• Check if switch is working properly by opening and closing the cabinet doors and see the light turning off/on. The timer should operate for 10
minutes before shutting off.
Warnings and Safety
A broken UV lamp is extremely unlikely to have any negative impact on your health. If a lamp breaks, ventilate the room for 30 minutes and remove
the parts while wearing gloves. Put the parts in a sealed plastic bag and take it to your local waste facility for recycling. Do not use a vacuum
cleaner.
CAUTION! The lamps are a Risk Group 3 Ultra Violet product. These lamps emit high-power UV radiation that can cause severe injury to the skin
and eyes. Avoid skin and eye exposure to unshielded product. Use only in an enclosed environment that shields users from radiation.