If you have any doubts about whether your appliance is working properly, we recommend to first
read suggestions below.
Tips & Tricks
When temperature or humidity in the appliance is out of range an alarm will be triggered.
Alarm sounds and alarm key is blinking on display.
To remove the sound, short press alarm key .
The temperature or humidity will be blinking on the display until it has been recovered.
If the alarm has not been removed and the temperature or humidity has been recovered, the alarm
sound will stop and blinking on the display will end.
Temperature out of range
CountermeasuresPossible cause
Try to minimize opening the door of the wine climate cabinet
appliance. Prepare loading plan of large quantities of bottles in
advance to minimize the required time for loading.
Frequent and/or long door
openings.
Try to use the ConnectLife mobile application as much as possible
to change appliance settings.
Making larger changes of the temperature settings may take the
appliance a few hours to reach new settings.
Recent big changes in
temperature settings.
Especially introduction of larger quantities of new bottles to the
appliance may take longer for the appliance to reach the set
temperature range.
Introduction of new bottles.
If possible, we recommend to introduce already cooled bottles to the
appliance.
We recommend to let the appliance cool down to the set temperature
before introducing the first batch of your wine bottles.
It may take a few hours for the appliance to cool to the requested
setting after being turned on.
Recent start-up of the
appliance.
We recommend to let the appliance cool down to the set temperature
before introducing the first batch of your wine bottles.
Make sure that the appliance is installed in a well ventilated room
and is not exposed to extremely high or extremely low temperatures.
For detailed appliance installation instructions please refer to the user
manual [see chapter Selecting the location].
Extreme ambient
temperatures.
In case none of the above countermeasures helped and the "temperature out of range" warning
persists, please contact a service center.