Loading ...
Loading ...
Loading ...
Installation
Installation
English30
Installation check codes
: LED ON, : LED Blink
Check code
Display Temp. Time (min.)
Drying Cooling
Wrinkle
Prevent
End
Extra
Low
Low Medium High 20 40 60 80
Ins
0
C80
C90
Ct
tC
C1
dC
9C1
Check code Meaning Solution
0 Vent condition is good.
Clg (Cg) The vent is clogged.
1. Clean the lint lter.
2. Check your vent condition.
(Refer to the “Ducting
requirements” section)
* You must take measures (such
as cleaning) through expert
personnel.
C80 (C8)
About 80 % of the vent is clogged.
(This may decrease the drying
performance.)
C90 (C9)
Over 90 % of the vent is clogged.
(This may lead to poor drying
performance or cause malfunction)
Ct
The internal temperature of the
dryer is too low (below 32 °F (0 °C))
or too high (over 104 °F (40 °C)) and
therefore, vent blockage cannot be
detected.
Leave the dryer at room
temperature (41
~
95 °F (5
~
35 °C))
for an hour and check again.
tC Temperature sensor error. Contact a service center.
C1
The unit is detecting items inside
the drum, or there is an error on the
dry sensor.
Remove items from the drum and
check again.
If the problem continues, contact a
service center.
DV3000A(SEM)_DC68-03784P-00_EN.indd 30 2020-12-07  4:50:56