Loading ...
Loading ...
Loading ...
Installation
English 29
3. Press and hold the Temp. and START/PAUSE buttons simultaneously for 3 seconds.
The Drying, Cooling, and High LEDs turn on.
If you have started other procedures before the Vent Blockage Test, the dryer will
not enter the Vent Blockage Test mode.
4. Press the START/PAUSE button.
The Vent Blockage Test starts immediately. During the test, the Drying, Cooling and
High LEDs blink.
Do not open the door during the test.
5. After 2 minutes, when the test is complete, the result is displayed and the dryer sounds
a tone.
If the status of the duct system is normal, the End LED turns on, and the dryer
sounds a completion tone.
If the duct system cannot exhaust properly, “Installation check code” is displayed on
the control panel, and the dryer sounds an alarm tone. For a description of the code,
see the “Installation check codes” section on page 30.
If there are any other problems, an information code appears in the display. For a
description of the code, see the “Information codes” section on page 48.
NOTE
During or after the test, the internal drum is hot. Use caution to prevent burns.
The Vent Blockage Test is used to check for problems to the current duct system when
the dryer is installed for the rst time.
If the test result displays check code (the duct system is blocked ), refer to the “Ducting
requirements” section on page 15 and the “Exhaust ducting guide” section below,
and then take proper measures to correct any problems.
If the test is suspended, it could result in incorrect results. Follow the proper
procedures when testing the dryer.
Even if the test result is normal (the End LED on), the duct system could be blocked
slightly. Properly install all ductwork according to the installation instructions in this
manual.
DV3000A(SEM)_DC68-03784P-00_EN.indd 29 2020-12-07  4:50:56
Loading ...
Loading ...
Loading ...