Only appliance owner/distributor may change the settings!
(owner/distributor should check Service manual)
DescriptionSettingOn display
Setting affect all programsno Drain --> max. rpmMax. RPM
Setting of draining via valve or
pump, depending on the type of
appliance; in case of change, a
mechanical change on the
appliance is required.
Valve/DrainDrain
In the Disinfection programs and
in the Special programs; this
means displaying the actual
measured temperature in the
drum.
On/OffShow temp
By changing settings it is
possible to create and customize
your own program.
On each program (some
settings cannot be set on some
programs)
Change program
Program can be renamed!
On/Off
• Prewash
°C/°F0 --> max
• Change temperature
no Drain --> max. rpm
• Change spin RPM
On/Off
• Water Level
On/Off
• Anti-crease
Once the above changes are
done, you can save the program
Override existing/Save as new
• Save program
as a new program or overwrite
an existing program.
At max. rpm in the Spinning
phase
0 --> 300Spin time
Choose either °C or °F.°C/°FTemperature unit
Additional rinses to the program
are added.
On/OffSuper rinse
With enabled function payment
is requested, to be able to start
the program.
On/OffPayment system
On/Off3D sensor