BUILT-IN CABINET INSTRUCTIONS FOR
MODEL CB377V
Make sure your installation does not block the front
ventilation grille. And be sure the door will open and
close properly in the chosen location.
ELECTRICAL CONNECTION
WARNING: Improper use of the grounded plug
can result in the risk of electrical shock. If the power
cord is damaged, have it replaced by a qualified
electrician or an authorized service center.
All electrical work should be carried out by a suitably
qualified and competent person in accordance with
local and national safety regulations.
Check that the voltage marked on the product
corresponds with your supply voltage.
Connect this appliance to a separate at least 13A
circuit.
Connection should be made via a suitable switched
socket which is easily accessible. For extra safety it
is advisable to install a residual current device (RCD)
with a trip current of 30mA.
Have the receptacle and the circuit checked by a
qualified electrician to ensure that the socket is
grounded correctly.
Note: In locations where there is frequent lightning,
it is advisable to use surge protectors.
Do not connect the appliance to the mains electricity
supply by an extension lead. Extension leads do not
guarantee the required safety of the appliance (e.g.
danger of overheating).
The appliance must not be connected to an inverter
and must not be used with a plug adapter as these
can cause damage to the appliance’s electronic unit.
The cord must rest securely behind the appliance
and not be allowed to lie or hang unprotected.
WARNING:
THIS APPLIANCE MUST BE EARTHED.
INSTALLING THE HANDLE FOR MODEL
CAV80X
IMPORTANT: Do not overtighten the screws & do
not use power tools to install the handle.
1
2
3
Locate the handle
â—‹
1 over the fixing pins
â—‹
3 of the
door and using the supplied allen key, tighten the
securing grub screws
â—‹
2 to fix the handle.