Rinnai 12 B Series Heat Pump OIM - Issue 1
SYSTEM SPECIFICATIONS
Model
EHPS215VM
Net Weight / Gross Weight 108 kg / 121 kg
Tank Volume 215 L
Sound Level 46 dB(A)
Ambient Temperature Limits
(for heat pump operation - element will
operate beyond these limits)
-7°C to 43°C
Ingress Protection IP24
Storage Cylinder - Hot Outlet and Cold inlet
Connections
ISO 7.1 ¾” RP
Storage Cylinder - PTR Valve Connection ISO 7.1 ¾” RP
Pressure & Temperature Relief (PTR) Valve
(Supplied) Setting / Rating
850 kPa / 46kW
ECV Fitted
Fit PLV if mains
pressure exceeds
680 kPa
Recommended PLV
pressure rating
500 kPa
ECV Not Fitted
Fit PLV if mains
pressure exceeds
800 kPa
Recommended PLV
pressure rating
500 kPa
Rated Input Electric Element
(Factory Wired)
2.1 kW
Maximum Input Refrigeration Module
(Factory Wired)
1.1 kW
Total Maximum Input 2.1 kW
Maximum Energy Output
(Use to size PTR)
4.5 kW
Power Supply 220V-240V AC/50 Hz.
Maximum Current 10 Amps (15 Amp plug tted)
Refrigerant Type / Mass R290 / 380 g
Refrigerant Circuit Maximum Pressure 3000 kPa
Coefcient Of
Performance (COP)
32.6°C Ambient
21.1°C cold water inlet
7.6
Heat Output
32.6°C Ambient
21.1°C cold water inlet
3.6 kW
SPECIFICATIONS
SPECIFICATIONS