7 Maintenance
30
T
Remove and empty the water tank�
T
Completely dissolve 3JURA descaling tablets in a receptacle
holding 600ml of water� This may take several minutes�
T
Pour the solution into the empty water tank and insert it into
the machine�
‘Press the Rotary Switch’
T
Place a receptacle under the hot-water spout and dual spout�
T
Press the Rotary Switch�
‘Machine is being descaled’, water flows straight into the drip
tray and out of the hot-water spout and dual spout repeatedly�
‘Empty drip tray’�
T
Empty the drip tray and coffee grounds container and put them
back into the machine�
‘Fill water tank’
T
Empty the receptacle and place it under the hot-water and dual
spouts�
T
Remove the water tank and rinse it thoroughly�
T
Fill the water tank with fresh, cold water and reinsert the tank�
‘Press the Rotary Switch’
T
Press the Rotary Switch�
Water flows straight into the drip tray and out of the hot-water
spout and dual spout repeatedly�
‘Empty drip tray’
T
Empty the drip tray and coffee grounds container and put them
back into the machine�
E If the descaling operation stops unexpectedly, rinse the
water tank thoroughly�