Loading ...
Loading ...
Loading ...
7 Maintenance
30
T
Remove and empty the water tank�
T
Completely dissolve 3JURA descaling tablets in a receptacle
holding 600ml of water� This may take several minutes�
T
Pour the solution into the empty water tank and insert it into
the machine
‘Press the Rotary Switch
T
Place a receptacle under the hot-water spout and dual spout�
T
Press the Rotary Switch
‘Machine is being descaled’, water flows straight into the drip
tray and out of the hot-water spout and dual spout repeatedly
‘Empty drip tray’
T
Empty the drip tray and coffee grounds container and put them
back into the machine
‘Fill water tank’
T
Empty the receptacle and place it under the hot-water and dual
spouts�
T
Remove the water tank and rinse it thoroughly�
T
Fill the water tank with fresh, cold water and reinsert the tank�
‘Press the Rotary Switch
T
Press the Rotary Switch
Water flows straight into the drip tray and out of the hot-water
spout and dual spout repeatedly
‘Empty drip tray’
T
Empty the drip tray and coffee grounds container and put them
back into the machine
E If the descaling operation stops unexpectedly, rinse the
water tank thoroughly
3x
Loading ...
Loading ...
Loading ...