USB Export / Import
19
The Oven controller is equipped with USB connectivity, through the USB port located on the lower right hand side of the control panel.
The set of programs, P01 - P30, stored in the controller memory can be:
• Written to a USB memory stick (Export).
• Replaced with a set of programs located on the USB stick (Import).
1. To export the set of programs from the controller to the USB stick:
• Ensure the oven is in ‘Standby Mode’ – ‘On / Off’ LED is lit.
• Insert a USB memory stick into the USB port.
• Upper display will show ‘USB’ and lower display will show ‘EPr’ (Export Programs).
• Press ‘Start / Stop’ button.
• Lower display will alternate between ‘rEv’ and ‘001’ (Revision Number e.g. 000 to 999).
(The set of programs can be given a different/new revision number at this point)
• Rotate ‘Timer’ Knob to select revision number required.
• Press ‘Start / Stop’ button to copy programs from controller to USB stick.
If an error message (Err, Er1 or Er2) appears in lower display, refer to
section ‘Fault Finding’
• Lower display will show ‘rUn’, followed by ‘dnE’ once copying is done.
• Remove USB memory stick from USB port.
• Controller will go back to ‘Standby Mode’.
The export feature is useful for backing up the set of programs created in the controller,
creating a copy of the set of programs to apply to another oven, and for editing programs
externally.
2. To import the set of programs to the controller from the USB stick:
• Ensure the oven is in ‘Standby Mode’ - ‘On / Off’ LED is lit.
• Insert a USB memory stick, containing at least one ‘MPRGRXXX.csv’ file into the USB port
(See Section ‘Import / Export Files’).
• Upper display will show ‘USB’ and lower display will show ‘EPr’ (Export Programs).
• Rotate ‘Timer’ knob to change to ‘IPr’ on lower display (Import Programs).
NOTE: IPr will not show on display if a ‘MPRGRXXX.csv’ file is not present.
• Press ‘Start / Stop’ button to copy programs from USB stick to controller.
• If more than one file is present, i.e. MPRGR001, MPRGR002…, the option to select between
these will appear:
• Lower display will alternate between ‘rEv’ and ‘001’ (Revision Number e.g. 000 to 999).
• Rotate ‘Timer’ Knob to select revision number required.
(A maximum of 10 revisions on the USB Stick will be selectable).
• Lower display will show ‘rUn’, followed by ‘dnE’ once copying is done.
• Remove USB memory stick from USB port
• Controller will go back to ‘Standby Mode’.
The import feature is useful for restoring a backed up set of programs, copying programs from another oven, and for loading
programs edited externally.
‘ON / OFF’ LED is ‘On’
when oven is in
‘Stand-By’ Mode.
‘Timer-Start / Stop’ LED
is ‘On’ when oven is in
’Stand-By’ Mode.