7
PRGM
SET
PRGM
SET
PRGM
SET
PRGM
SET
PRGM
SET
PROGRAMMING UP TRAVEL LIMIT
Steady Blue
HOLD
UNTIL
LED
Lights
Flashing
Blue
RELEASE
1-2. Enter Programming Mode
3. Adjust Door Position
4. Lock Programming
Flashing
Blue
PRESS
&
RELEASE
1. Press and hold the UP arrow button.
tLong LED will light BLUE.
2. Release UP arrow button.
tRound LED will ash BLUE.
3. Press and hold the UP arrow button until door is
fully open.
tUse the DOWN arrow button if door opens too
far. Use both UP and DOWN buttons to adjust
open travel as necessary.
Door should fully open so that door seal is even with
door header. Do Not adjust so much that the door will
bend or buckle or stretch door spring cables backward.
4. Press and release the SET/PRGM button
tBoth LEDs will ash BLUE then go out.
5IF61MJNJUJTOPXQSPHSBNNFE
Programming UP Limit:
Correct
Angle
Incorrect
Angle
Proper UP limit setting
UP limit set too high
One-Piece Door Limit Setting
Fig. A
SECTIONAL DOOR UP LIMIT:
Door should fully open so that door seal is even with
door header. Do not adjust so much that the door will
bend, buckle or stretch door spring cables backward. Stop
carriage short of the opener powerhead.
ONE-PIECE DOOR UP LIMIT:
Door should fully open so that the door arms will be in
line and push forward and up on the door.
%PPSEBNBHFDBOSFTVMU If up limit is set too far back and
door arms are angled downward pushing against the
natural travel direction. Fig. A