17
INSTALLATION INSTRUCTION
3-Wire system connections
1. Connect the grounding wire of the power cord to the external
screw. If there is no the power cord
2. Remove the two side terminal block screw and connect the other wires to the
outer terminal screws. Be sure to cross the screw through the terminal ring and
tighten the screw.
3. Tighten the strain relief screws.
4. Insert the tab of the terminal block cover into your dryer's rear panel slot. Secure
the cover with a screw.
ground conductor
grounding wire of , please remove the Neutral
grounding wire from center terminal block screw of the dryer, then connect it to
the external ground conductor screw and connect the neutral wire to the center
terminal block screw.
- Ring-type terminals are recommended. If using strap
terminals, make sure they are tightened.
WARNING
4-Wire
receptacle
(14-30R)
Four wire outlet
Then choose a 4-wire power supply cord with ring terminals and
UL listed strain relief. The 4-wire power supply cord, at least
4.92 ft. (1.5 m) long, must have 4 10-gauge solid copper wires and
match a 4-wire receptacle of NEMA Type 14-30 R, rated 120/240V,
min 10A. The ground wire (ground conductor) may be either green
or bare.The neutral conductor must be identified by a white color.
4-Wire system connections
1.
2.
3.
Remove the center terminal block screw.
Connect the ground wire (green or unwrapped) of the power cord to the external
ground conductor screw.
Connect the neutral wire (white or center wire) of the power cord and the appliance
ground wire (white) under the center screw of the terminal block. Be sure to cross the
screw through the ring of the power cord terminal and tighten the screw.
Connect the other wires to the outer terminal block screws. Be sure to cross the
screw through the terminal ring and tighten the screw.
4.
3-Wire system instructions:
A Center terminal block screw
B External ground connector
C Neutral grounding wire (White)
D Neutral wire (white or center wire)
E 3/4" (1.9cm) UL-listed strain relief
A
B
C
D
E
Loading ...
Loading ...
Loading ...