Loading ...
Loading ...
Loading ...
19
1 (844) 334-4203
www.thermomate.com
Live Smart, Better Life!
Installing - Electrical Connections
A. When making the wire connections, use the entire length of conduit
provided. The conduit must not be shortened.
B. With the cooktop in place, open the front of the cabinet door.
C.Insert the wires from the conduit through the opening of the junction box.
D. Connect the red and black leads from the cooktop conduit to the
corresponding leads in the junction box.
E. Once the connections are made, secure wires together using wire nuts.
Grounding instructions:
The bare ground wire in the conduit is connected to the cooktop frame. Effec-
tive January 1, 1996, the National Electrical Code will not permit grounding
through neutral. If used in new construction after January 1, 1996 or in a
mobile home, recreational vehicle or if local codes do not permit grounding
through the neutral white lead, attach the appliance grounding lead(green or
copper) to the residence grounding conductor (green or bare copper) in
accordance with local codes.
When connecting to a 3 conductor branch circuit, if local codes permit, connect
the bare ground connector lead of the cooktop to the branch circuit
neutral(gray or white in color).
Strain Relief Clamp
Black
Red
Ground
Black
Red
Ground wire location
Strain Relief Clamp
Black
Red
Ground
Loading ...
Loading ...
Loading ...