NOTE: During this time the room humidity level will continue to be monitored and
the humidifier wil! cycle the fan on and off until the filter is completely dry, The fan
will shut off leaving you with a dry humidifier that is less prone to mold and mildew
growth. If DRY OUT MODE is not desired, refill the humidifier with water and the
fan will return to the set speed.
NOTE: Fan automatically switches to lowest speed during DRY OUT MODE
Check Filter indicator
The ability of any humidifier to efficiently supply
humidity output relies heavily on the condition
of the filter. As the filter loads with impurities it
gradually loses its wicking capability. When this
happens, moisture output is reduced and the
humidifier has to work longer to satisfy the
selected setting. This humidifier has a check
filter reminder timed to appear after 720 hours
of operation. When display shows an
alternating "CF" and "room humidity" setting at
5 second intervals it is a reminder to check the
filter condition°
Ctl#{;k r,tlt{_r
Display
Humidistat
The humidistat located on the power
cord senses the percentage of
humidity in the air. tt causes the
humidifier to cycle on and off to
maintain the selected humidity SET
point° The fan will turn on if the
"ROOM" reading falls 3% below the
SET point and will continue to run the
humidifier until a reading of 1% above
the SET point is achieved. The fan
wilt turn off until the ROOM reading
falls 3% below the SET point again.
NOTE: Be sure that the humidistat,
which is located on the power cord, is
free from obstruction and away from
any hot air source,
Control Lock Out
To avoid unwanted tampering with the
humidifier settings the controls can be
locked,
Activation Procedure
After the humidifier functions have been
set up, hold the power button down for
5 seconds° The display will show "CL"
for 2 seconds; release the power button
and the control will resume the display
of the room humidity. The room
humidifier will continue to function with
the locked in settings, If buttons are
operated while "CL" is active, the "CL"
is displayed and settings are
unaffected,
Deactivation Procedure
To deactivate the "CL" function simply
press and hold the power button for 5
seconds. "CL" will flash at the rate of t
second on and 1 second off for a period
of 2 seconds and then resume the
display of room humidity.