DGS-1250 Series Gigabit Ethernet Smart Managed Switch Hardware Installation Guide
18
Set the data rate to 115200 baud.
Set the data format to 8 data bits, 1 stop bit, and no parity.
Set flow control to none.
Figure 4-1 COM Port Configuration
To be able to view the boot procedure, the Switch needs to be rebooted. The simplest way, at this stage, to reboot the
Switch is to unplug and re-insert the power cable from and into the power receptacle on the back of the Switch.
After correctly configuring the terminal settings and re-inserting the power cable, the boot procedure will appear in the
terminal.
Loader Procedure
-------------------------------------------------------------------------------
Please Wait, Loading 2.03.001 Runtime Image ............... 100 %
UART init ................................................. 100 %
Starting runtime image
Device Discovery .......................................... 100 %
Configuration init ........................................ 100 %
After the boot sequence has been completed, the console login screen will be displayed.
Connecting to the Switch for the First Time
The Switch supports user-based security that can prevent unauthorized users from accessing the Switch or changing
its configuration. This section will explain how to log into the Switch’s Command Line Interface via the out-of-band
console connection.