Onlycertaincooktopmodelsmaybeinstalled
overcertainbuilt-inelectricovenmodels,listedby
theMFGIDnumber(seetheinsertsheetincluded
intheliteraturepackage).
s"
To reduce the risk of
personal injury and
tipping the wall oven,
the wall oven must be
secured to the cabinet(s)
by properly installed
mounting screws.
208/240V junction box for
built-in oven.
4 I/2"
(11.4 cm)
Max.*
Side filler panels are necessary to
isolate the unit from adjoining
cabinets. Panel height should
allow for installation of approved
cooktop models.
36" Min.
(91.4 cm)
Use 3/4" (1.9 cm) plywood, installed
on two runners, flush with toe plate.
Must be capable of supporting 150
pounds (68 kg).
Cut an opening in wood base
minimum 9" x 9", 2" (23 x 23, 5
cm) from left side filler panel, to
route armored cable to junction box
or fuse box.
* If no cooktop is installed
directly over the oven unit, 5"
(12.7 cm) maximum is
allowed.
27" (68.6 cm) 24 7/8" (63.2 cm) Min. 28 1/8" (71.4 cm) Min.
Wall Oven 2B 1/4" (64.1 cm) Max. 23 1/2" (59.7 cm) Min. 28 5/8" (72.7 cm) Max.
Figure 12- SELF CLEAN MODELS ONLY
TYPICAL UNDER COUNTER INSTALLATION OF AN ELECTRIC BUILT-IN OVEN
WITH AN ELECTRICCOOKTOP MOUNTED ABOVE