Loading ...
Loading ...
Loading ...
10
Drain pump kit
You may order the ice maker with or
without a drain pump. In the case of the
model with no drain pump, water is
drained by gravity.
However, it is possible to install a drain
pump kit on the gravity drain pipe model
if you wish convert the model to a
drain pump model.
You may obtain the necessary parts for
conversion from the distributor. You may
obtain information on the local agencies
and distributors in the store section of
the company’s website, .
A detailed description of installation is
included in the kit.
Fig. 6 Top View
Fig. 7 Front View
Drain Pump Model
1) Arrange the ice maker at the front of the opening
of installation.
2) Adjust the horizontality leg so as to meet the height.
3) Install the inlet pipe (copper pipe with a diameter
of 1/4”) on the wall and connect the water supply
valve.
4) Connect the drain pipe from the wall to the
ice maker.
Important Information :
An air gap may be required
between the drain tube of the ice maker and the container
of the drain pipe under the provision of local laws
and regulations. Refer to the drawing below.
5) If the electric outlet is at the back of the product,
nsert the plug into the electric outlet.
6) Install the product so that the front of the product is
facing forwards.
7) Use the inlet pipe after cutting the required length.
8) Wash the inlet pipe. Connect the inlet pipe
with the copper pipe using the flare nut.
9) Connect the inlet pipe with the water-supply valve
of the pro duct using the flare nut.
10) Cut the required length of drain tube.
11) Connect the drain tube (with a diameter of 5/8“)
with the drain pipe at the back of the product and
fix them together using a hose clamp. If required
for easy installation, immerse the drain hose
in warm water just before connection with the
fitting.
12) Turn on the tap and check where there is any
leakage.
13) Pour 3 quarters of the water into the ice container.
The drain pump should work and pump the water
upwards. Check whether the drain pump works
or not. Check for any leakage.
14) Turn the switch to the “ICE" position.
The compressor starts working 3-5 minutes.
15) Pour 3 quarters of water into the ice container
and block the drain tube while the drain pump
is operating. At this time, check whether
the operation has stopped and that the drain
pump works continuously.
16) Adjust the horizontality of the product.
Important Information :
Piping should be carried out
in accordance with all the provisions laid out under
the local laws and regulations.
Loading ...
Loading ...
Loading ...