Four-wire connection...
Four-wire receptacle
4. Remove center terminal block
screw.
5. Remove appliance ground wire --
(green with yellow stripes) from
external ground connector screw.
Fasten under center, silver-colored
terminal block screw.
6. Connect ground wire (green) of
power supply cord to external
ground conductor screw. Tighten
screw.
7. Connect neutral wire (white or
center) of power supply cord under
center screw of the terminal block.
Tighten screw.
8. Connect the other wires to outer
terminal block screws. Tighten screws.
9. Tighten strain relief screws.
10. Insert tab of terminal block cover
into slot of the dryer rear panel. Secure
cover with hold-down screw.
4. Remove center terminal block screw.
5. Remove appliance ground wire
(green with yellow stripes) from
external ground connector screw.
Fasten under center, silver-colored
terminal block screw.
6. Connect the ground wire (bare)
of the power supply cable to the
external ground conductor screw.
Tighten screw.
7. Place the hooked end of the
neutral wire (white or center) of
power supply cable under the center
screw of terminal block (hook facing J
right). Squeeze hook end together.
Tighten screw.
8. Place the hooked ends of the
other power supply cable wires /
under the outer terminal block screws /
(hook facing right). Squeeze hooked / /
ends together. Tighten screws. /J
//
9. Tighten strain relief screws. /J
V
10. Insert tab of terminal block cover
into slot of dryer rear panel. Secure
cover with hold-down screw.