Mr. Heater, Inc. | Kerosene Fired Radiant Heater Operating Instructions and Owner’s Manual
5
DIAGNOSTIC SAFETY SHUTDOWN AND TROUBLE SHOOTING
FAULT CAUSE SOLUTION
Motordoesnotstartandnoignition
Noelectricalcurrent
Checkpowersupply(isitpluggedin?)
Checkproperpositionoftheswitch(isiton?)
Checkfuse/breaker
Wrongsettingonthermostat Checkforsettingofthermostathigherthanroom
temp.
Defectivemotor ReplaceMotor
Motorstartsnoignitionorcutsout
Notenoughfuelattheburner
Ensureanadequateleveloffuelisinthetank.
Cycleunitafewtimetoallowfueltofillthefilter
andfuelsystem.
Checkfuellinesincludingfilterforleaks.
Cleanorreplacenozzle.
Electronicigniterdefective
Checkigniterconnectionsincludingtransformer
Checkelectrodesforcorrosionandcarbonbuildup.
Replacetransformer
Flamecontrolboxdefective Replaceflamecontrolbox
Photocelldefective Cleanorreplacephotocell
Solenoiddefective
Checkconnections
Replacesolenoid
Motorstarts,heateremitssmoke
Notenoughcombustionair
MakesureAirinletandoutletarefree
Cleanburnerdisc
Fuelcontaminatedorcontainswater
Drainfuelintankandreplacewithcleanfuel
Cleanorreplacefuelfilter
Airleaksinfuelcircuit Checkfuellinesandsystemforpossibleleaks
Notenoughfuelatburner Cleanorreplacefuelnozzle
Toomuchfuelatburner Replacenozzle
Heaterdoesnotstop Solenoiddefective Replacesolenoid
LED DIAGNOSTIC READ OUT TABLE
ERROR CODE DESCRIPTION
E1 Ignitionfailedorflameout
E2 Temperaturesensormalfunction
E3 Highlimitswitchoverheat
E4 Flamecontrolmalfunction
E5 Solenoidmonitormalfunction
E6 Photcellfault
E7 Motorspeedfault
DEFAULT T-STAT SETTING T-STAT RANGE
68°F 41°F-99°F