DRAPER 70551 12/24V Battery Starter/Charger, 500A

User Manual - Page 19

For 70551.

PDF File Manual, 24 pages, Read Online | Download pdf file

70551 photo
Loading ...
Loading ...
Loading ...
  





Stock No.70552
START
P. MA X
P.MAX
3.0KW
15KW
Output Fuse 150A x2
EN 60335-2-29
3s ON/120s OFF-5cycle
230V~1ph
50 Hz
U
1
CHARGE
START 12V
CHARGE 12V
Cmin 20 AhIP 20 cl H
120A
120A
CHARGE 24V
START 24V
800A(1V/e)
800A(1V/e)
70551 & 70552
- FIG 9
Output voltage selection is achieved by connecting the positive (+) red clamp cable to the
appropriate terminal  12V or  24V. Connect the cable to the terminal and securely tighten
locking knob.
The battery terminal not connected to the chassis has to be connected first. The other
connection is to be made to the chassis, remote from the battery and fuel line. The battery
charger is then to be connected to the supply mains.
To select the one of the 4 output amperage/charge speed settings rotate the switch as
applicable.
1. Low amperage/charge speed.
2. Medium/Low amperage/charge speed.
3. Medium/High amperage/charge speed.
4. High amperage/charge speed (USED IN CONJUNCTION WITH TIMER ONLY).
Position switch  and observe the output current.
Select the position with the output amperage approaching the 10% figure (5% for deep
discharge). Should the setting exceed 10% (5% for deep discharge) switch down until a suitable
output is attained and begin charging.
Position 4 is used in conjunction with the 60 minute timer . Select position 4 and rotate the
timer for the desired recharge time. When the timer reaches zero the charge current will stop.
After charging, disconnect the battery charger from the supply mains. Then remove the chassis
connection and then the battery connection.
FIG.9
Stock No.70552 shown
9. OPERATION AND USE
- 19 -
Loading ...
Loading ...
Loading ...