User guide
Billi Quadra & Quadra Plus – XL, XT, XR.
Normal Display Current status may be displayed as follows
TIMESWITCH ON/OFF Indicates the Quadra has been switched ON or OFF by the inbuilt time
switch control. During OFF mode, the dispenser icons are o and give
a brief orange flash once every 10 seconds.
OVERRIDE ON/OFF The Quadra can be manually turned ON or OFF by pressing the
ON/OFF button. The status remains as selected for a period
of 2 hours, after which it returns to automatic ON/OFF control.
LOCKED ON/OFF The ON/OFF status can be permanently locked ON or OFF. Use ON if
24 hour, 7 days a week service is required; or OFF if user is going away
for an extended period. To activate or deactivate: press the
ON/OFF
button and hold down until the required status is displayed.
SAFETY SWITCH The child proof safety Switch mode has been activated. To set,
refer to Options, page 7.
STANDBY A period of non-use has elapsed and the Quadra has switched to
the energy saving standby mode.
Daylight saving
Time adjustment for daylight saving is
made by pressing either the START or
FINISH buttons at the beginning or end
of daylight saving.
Menu
To access the menu, press the
SELECT
button. The menu functions are:
To move the highlighted cursor, press
the
or buttons.
To activate the highlighted cursor,
press
SELECT.
To return to previous screen, press
BACK.
—Setting time and date
Screen shows currently set time, day and date.
Press
or buttons to move the highlighted
cursor.
Press
SELECT to activate. The highlighted
item flashes.
When flashing, press
or to change
setting.
Press
SELECT. Highlighted cursor stops
flashing. Cursor automatically advances
to next setting. Repeat above activation
procedure.
Press
BACK once to return to previous
screen or twice to return to normal display.
Set up Instructions
Model 4100 J01670000
SW: 8.26 09:51 AM
Tue 01 JAN 2013
LOCKED ON
Quadra
Normal display
Model
Software
version
Day and date
Serial number
Time
Current status