Mounting instructions
Technical specifications
Instant water heater model
Electric supply
Nominal power rating
Elex 8.5
220-240V 50/60Hz
8.5 kW
Elex 12
220-240V 50/60Hz
Nominal current
Flow rate (∆t=45°F)
Flow rate (∆t=65°F)
Cable size
Temperature range
Switch on flow rate
Non-usage consumption
Protection class
Type of protection
Dimensions
Unit weight
Water connections
Max. pressure water mains
Switch on flow pressure
32-35 A
1.3 GPM
0.9 GPM
10 AWG
104-140 °F
0.58 GPM
<1 Wh/h
I
IP 24
13⅝ x 7⅞ x 4¾''
5.4 lb
1/2’’ NPT
115 PSI
15 PSI
46-50 A
1.8 GPM
1.3 GPM
8 AWG
104-140 °F
0.58 GPM
<1 Wh/h
I
IP 24
13⅝ x 7⅞ x 4¾''
5.4 lb
1/2’’ NPT
115 PSI
15 PSI
12 kW
Commissioning
Fill the device and vent it by opening a hot water tap connected to it.
Only switch on the electrical supply once the device is clear of any
air.
Check the operation of the device.
Frost
This device should be installed in a climate-controlled location,
protected from freezing temperatures.