13
Electric tankless Water heater - Installation Maunal and User Guide
TM
Mounting instructions
See image A7, A8, A9,
The electrical connection should be made by a qualitied electrician, in
accordance with the relevant regulations (IEC, NEC, etc.)
The device has been ready to connected to the electrical supply.
Press the red button shown in image A9 to reset the switch.
Cut the cable to the required length and connect it to the terminal
block. Use the supplied cable boot to obtain a good seal.
This appliance must be earthed.
See image A1, A2
Remove the screw with a philips-head screwdriver and open the top
cover. Remove the display plug and remove the top cover and put
aside.
Installation, See image A3, A4, A5
1. Use two pieces of tape to fix the template on the wall where the
device is to be installed.
2. Drill two 5/16” holes through the template, as indicated.
3. Bear in mind where the water pipes will be installed later.
See image A6
1. Install the device with the supplied screws and anchors.
2. The cold water supply should be connected to the inlet on the right of
the device (blue=cold water).
3. The hot water pipe is installed to the left. Make sure the connections
are water tight! To prepare the connection to the water supply, Teflon
tape must be used for sealing the threads.
See image A10, A11
• Insert the display plug.
Install the top of the housing.
Insert the screw at the bottom.
The appliance must be earthed properly!
The filter mat contained in accessory bag must be installed
when connecting with inlet(cold) water pipe or hose!
Circuit breaker must be installed with the appliance, please
take page.15 to 17 for the selection of circuit breaker.