16
© 2021 United States Stove Company
MILLIVOLT CONTROL
Thermocouple
for Natural
Thermocouple
for LP
Thermocouple
for LP
Thermocouple
for Natural
PILOT
OFF
BURNER FLAME
In normal operation at full rate after 15 minutes, the
following ame appearances should be observed:
The left and right rear ames should be yellow and
extend 1”- 2” above middle logs. The yellow ames
should not contact the logs. There should be
glowing embers on the front surface of the middle
log. NOTE The ames and embers will be an opaque
orange color during the burn off time.
OPERATING INSTRUCTIONS
Avoid any drafts that alter burner ame patterns.
Do not allow fans to blow directly into the stove.
Do not place a blower inside the burn area of the
stove. Ceiling fans may create drafts that alter
ame patterns. Sooting and improper burning
will result. During manufacturing, fabricating and
shipping, various components of this appliance are
treated with certain oils, lms or bonding agents.
These chemicals are not harmful, but may produce
annoying smoke and smells as they are burned off
during the initial operation of the appliance, possibly
causing headaches or eye or lung irritation. This is a
normal and temporary occurrence. The initial break-
in operation should last two to three hours with the
burner at the highest setting. Provide maximum
ventilation by opening windows or doors to allow
odors to dissipate. Any odors remaining after this
initial break-in will be slight and will disappear with
continued use.
For Your Safety Read Before Lighting
WARNING:
IF YOU DO NOT FOLLOW THESE INSTRUCTION
EXACTLY, A FIRE OR EXPLOSION MAY RESULT
CAUSING PROPERTY DAMAGE, PERSONAL
INJURY OR LOSS OF LIFE.
A. This appliance is equipped with an ignition
device which automatically lights the pilot. If
the piezo is not working properly, refer to Match
Lighting instructions.
B. BEFORE OPERATING smell all around the
appliance area for gas. Be sure to smell next to
the oor because some gas is heavier than air
and will settle on the oor.
WHAT TO DO IF YOU SMELL GAS:
Turn off all gas to the appliance.
Open windows.
Do not attempt to light any appliance.
Do not touch any electric switch; do not use any
phone in your building.