COMMISSIONING
83
11. Switch DIP switch 3 to the on (up) position on the PCB.
The current outlet temperature setting will show on the LED
display.
12. AU 876 series: Press the MAX button once to increase the
outlet temperature setting to the next increment.
The MAX button is located below the DIP switches and adjuster
button, and above the MIN button.
Each press of the MAX button will increase the outlet
temperature setting by one increment.
The outlet temperature setting will show on the LED display.
The outlet temperature setting increments above 48°C are:
50°C, 51°C, 52°C, 53°C, 54°C*.
(* 54°C applies to 876 series 812, T16, 820 models only)
13. NZ 874 series: Press the MIN button once to decrease the
outlet temperature setting to the next increment.
The MIN button is located below the DIP switches, adjuster
button and the MAX button.
Each press of the MIN button will decrease the outlet
temperature setting by one increment.
The outlet temperature setting will show on the LED display.
The outlet temperature setting increments below 55°C are:
54°C, 53°C.
14. Switch DIP switch 3 to the off (down) position on the PCB.
The LED display will go blank.
Note: Wait five (5) seconds for the setting to be saved.
15. Check the water temperature at the hot tap by repeating steps 2
to 5.
16. AU 876 series:
if the water temperature is still below 50°C and requires to
be increased, repeat steps 11, 12 and 14, followed by
steps 2 to 5 until an acceptable water temperature not
exceeding 50°C is measured at the same hot tap.
if the water temperature exceeds 50°C then;
switch DIP switch 3 to the on (up) position on the PCB.
The outlet temperature setting will show on the LED display.
press the MIN button once to decrease the outlet temperature setting to the next increment.
Each press of the MIN button will decrease the preset temperature by one increment.
The MIN button is located below the DIP switches, adjuster button and MAX button.
switch DIP switch 3 to the off (down) position on the PCB.
The LED display will go blank.
Note: Wait five (5) seconds for the setting to be saved.
repeat steps 2 to 5 to confirm the water temperature does not exceed 50°C.