NOTE: For your convenience, the charger can operate with most generators and
inverters rated at 300 watts or higher.
LED FUNCTIONS OF CHARGER (Fig. 3)
LED INDICATOR
HI/LO TEMP. O"
(SEE MANUAL)
BATTERY
BATTERY
CHARGING
BATTERY "_
FULL
BATTERY
PACK
Hot/Cold
battery
Defective
Charging
Fully
charged
RED
LED
On
Flashing
Off
Off
GREEN
LED
Off
Off
Flashing
On
ACTION
Charging will begin
when battery returns to
32°F (0°C)-104°F (40°C)
Battery pack or
Charger/Adapter is
defective
Charging
Charging is complete
Maintenance charging
CHARGING A HOT BATTERY PACK
If the battery pack is above normal temperature range, the red LED will
illuminate and the green LED will be off. When the battery pack cools down to
approximately 104°F (40°C), the charger will automatically begin charging.
CHARGING A COLD BATTERY PACK
If the battery pack is below the normal temperature range, the red LED will
illuminate and the green LED will be off. When the battery warms to a temperature
of more than 32°F (0°C), the charger will automatically begin charging.
DEFECTIVE BA'n'ERY
If the charger detects a problem, the red LED will begin flashing and the green
LED will be off.
.
.
.
If registering as defective, remove and reinsert the battery pack in the
charger. If the LED status reads "defective" a second time, try charging a
different battery pack.
If a different battery pack charges normally, dispose of the defective battery
pack (see Maintenance section).
If a different battery pack also indicates "defective," the charger may
be defective.