GE - General Electric JGBP25EEL4BB GE gas range

User Manual - Page 45

For JGBP25EEL4BB.

PDF File Manual, 56 pages, Download pdf file

Loading ...
Loading ...
Loading ...
Installation instructions
[] iNSTALLiNG THE ANTI-TIP
DEVICE
A WARNING!
Range_ must be secured with an approxed Anti-Tip
device.
Unless properly instnlled, the range could be tipped
by you or a child standing, sitting or leaning on an
open dooi;
Mter instnlling the Mlti-Tip device, \'erit_, that it is in
place by caretully attemi_ting to tilt rite range flwward.
This range has been designed to meet all recognized
industry tip standards fin" all nmmal conditions.
The use (ff this device does not preclude tipping of
the range when not properly installed.
If the Anti-Tip device supplied with the range does
not fit this application, use the tmive_al Anti-Tip
device WB2X7909.
A. Mark the wall where the RIGHT EDGE (ff the range
is to be located. Be sine to allow fin" the counte_op
oxvflmng if you intend to install the range next to
cabinets.
SIo_ed head
screw
Marked edge of range
B. Locate the outside edge of the device 2¼" toward
the center of the range fl'om the marked edge of
the range.
C. Using the device as a template, mark the position of
the hole fi)r the screw.
D. For x_ood construction, drill a pilot hole at ,an ,'m,,le
of 20 degrees from the horizontal. A nail or awl
max be used if a drill is not available.
Motmt the Anti-Tip device Mth the screw pr(Mded.
For cement or concrete construction, you will need
a 1/4" x 1½" lag bolt and a 1/2" O.D. sleeve anchol;
which are not provided. Drill the recommended size
hole %r the hardware.
[] INSTALLING THE ANTI-TIP
DEVICE (CONT.)
Wallboard
Wood screw
Back of range
Install the sleeve anchor into the drilled hole and then
install the lag bolt through the device. Tile bolts must be
properly tightened as recommended fin" the hardware.
E. Slide the range against the wall, and check fi)r proper
installation by grasping the front edge of tile cool<top
and carefully attempting to tilt the nmge fiwward.
WHEN ALL HOOKUPS ARE
COMPLETED
Make sure all controls axe left in the off position. Make
sure the flow of combustion and ventilation air to the
range is unobstructed.
CONVERTING TO LP GAS (or
converting back to natural gas from LP)
This rmlge leaves the factory set for use with natural gas.
If you want to convert to LP gas, the conversion must be
performed by a qualified LP gas installer.
The conve_ion instructions and I,P OlJfices (aI1 be fimnd
attached to the range next to the pressm'e regular(n:
Keep these instructions and the orifices in case wm want
to convert back to natm'al gas.